undefined
+
  • undefined

Product

Machine Safety

Safety Relay

SR-C16L

No.:

Products specially designed for safety light curtain, emergency stop switch,reset button, safety door switch,Comply with the standards ofIEC/EN60947-5-1,EC/EN60204-1 and VDE 0113-1,3 Series safety contacts are NO and l parallel auxiliary contact is NC,Manual or automatic reset,Open the status channels CHl, CH2 and the power LED indicator light

Retail price:

$ 100

Market price:

$ 50

Quantity:
-
+

Remaining stock:

1000

  • Specifications
    • SR-C16L
Compare
Close
  • Product Comparison
Total X Clear all

隐藏域元素占位


Product Description

Detail display

Model Description

Safety relay SR-C16L supports machine protection with light curtains, emergency stops, reset buttons, and safety doors. It has two input channels, three normally open safety contacts, and one normally closed auxiliary contact.

Manual or automatic reset and status indicators support integration. Confirm voltage and wiring needs before installation, and contact us for more product information.

Serial NumberSelect ItemDetails
1SeriesS:Safety series
2FunctionR:Emergency shutdown
3Input voltageC:24~240VAC/DC(Decided by Lin ⑥);24VAC/DC(Decided by Pin⑥)
4

Contact configuration

(safety output)

1:SPST-NO
5

Contact configuration

(auxiliary  output)

6:1NC
6Enter configurationL:(2-channel input and ③combination use;24VAC/DC(use by ③combination)

 

Main ContactAuxiliary Contact

Number of Input

Channels

Reset ModeType of lnputRated VoltageModel
SPST-NOSPST-NC2 ChannelsAutomatic/manual

+Common mode

(Note  1)

24~240 VAC/DCSR-C16L
SPST-NOSPST-NC2 ChannelsAutomatic/manual

+Common   mode

(Note  1)

24VAC/DCSR-C16P

 

Specifications

                      Model

Item

SR-C16T

SR-C16P

Power Input24~240AC/DC:50~60Hz24VAC/DC:24VAC/DC
Operating Power Range85~110%of the rated power supply voltage

Power Consumption

4.5VABelow 2.5W

When DC24V,the Voltage and Current of the Input Circuit

40mA50mA

When DC24V,the Voltage and Current of the Reset Circuit

40mA50mA

When DC24V,the Voltage and Current of the Feedback Circuit

40mA50mA

Safety Contact(EN60947-4-1):(AC1240V)

Imin:0.01A,Imax:6.0A Pmax:1500VA

Safety Contact(EN60947-4-1):(DC124V)

Imin:0.01A,Imax:6.0A Pmax:1500W

Auxiliary Contacts(EN60947-4-1):(DC124V)

Imin:0.01A,Imax:6.0A Pmax:1500VA

Auxiliary Contacts(EN60947-4-1)

DC124V,Imin:0.01A,Imax:6.0A Pmax:150W

Safety Contact(EN60947-4-1):(AC1230V)

Imax:5.0A5.0A

Safety Contact (EN60947-4-1):DC124V(6 cycles/minutes)

Imax:6.0A6.0A

Auxiliary Contact(EN60947-4-1):AC1230V

Imax:5.0A5.0A

Auxiliary Contact(EN60947-4-1):DC124V(6cycles/minutes)

Imax:6.0A6.0A

Output contact count

3 Safety contact(NO),instantaneous 1 auxiliary contact(NC),instantaneous

Connector Resistance(Note 1)100mΩ
Insulation resistance(Note 2)Above 100mΩ(DC500V)
Rated Insulation Voltage250V
Overvoltage categoryLevel II/Level lI

 

Input Circuit,Reset the Maximum

Resistance of the Circuit Cable Total

DC power supply:single channel30 Ohm45 Ohm
AC power supply:single channel100 Ohm45 Ohm
DC  power  supply:dual-channel  does  not detect  short  circuit  between  contacts50 Ohm80 Ohm
ACpower  supply:dual-channel  does  not detect  short  circuit  between  contacts100 Ohm80 Ohm
AC power supply:short circuit between dual-channel  detection  contacts15 Ohm 
AC power supply:short circuit between dual-channel  detection  contacts15 Ohm

 

 

Time

Connection

Delay

With automatic reset(maximum)400ms450ms

he time of aytomatic reset after power

on(maximum)

450ms800ms
Manual reset time(maximum)400ms450ms

Emergency

Stop Delay

Emergency stop(maximum)30ms20ms
Maximum voltage  interruption  before power  failureAbout 25ms

 

Insulation Strength

Between different outputs

 

AC2,500V,50/60Hz(1 Minute)

Between input and output
Between power input and output
Vibration Resistance10~55~10Hz,0.375mm Single amplitude(0.75mm double amplitude)
Impact ResistanceDurable300m/s²
Breakdown100m/s²
Durability(Note 3)MachineryAbove 10,000,000 times operation
ElectricalAbove 80,000 times operation
Failure Rate(Level P)(Reference Value)DC5V,1mA
Ambient Temperature-10℃~+55℃(no icing or condensation)
Ambient Humidity35~95%RH(Non-condensation state)
Terminal Fastening Torque0.5N.m
 

Circuit diagram

Internal wiring diagram

Dimension Diagram

Outline Dimension

Production Process

Exhibition Site

Learn more about product content

  • File size: 7.3MB

Keyword:

SR-C16L

Related products

Get A Quote

Tell us more so we can connect you with the right person for your request.

SUBMIT
%{tishi_zhanwei}%

Get A Quote

Our sales team will provide you with a detailed quotation within 24 hours.
Whether your needs are for a single product or a complete customized solution, we will provide a tailored quotation and technical support based on your specific requirements.

Deputy General Manager
Mr. Lin
Phone: 135880666646
Whatsapp: 135880666646

Sakady

Deputy General Manager
Mr. Lin

Phone: 135880666646
Whatsapp: 135880666646

Sakady
Overseas Marketing Manager
Lucia Jiang

Phone: +86 18616850611
WhatsApp: +86 18616850611

 

Sakady

Consult Now

Submit
%{tishi_zhanwei}%